[v2,2/7] arm64: dts: ti: iot2050: Disable R5 lockstep for all PG2 boards
Commit Message
From: Baocheng Su <baocheng.su@siemens.com>
The R5 lockstep disabling should be common for all PG2 boards, move it
from variants dts to common-pg2.dtsi.
As now the Basic PG2 consumes this twice, move Basic disabling to the
PG1 variant.
Signed-off-by: Baocheng Su <baocheng.su@siemens.com>
[Jan: avoid duplication of disabling for Basic PG2]
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
---
arch/arm64/boot/dts/ti/k3-am65-iot2050-common-pg2.dtsi | 7 ++++++-
arch/arm64/boot/dts/ti/k3-am6528-iot2050-basic-common.dtsi | 5 -----
arch/arm64/boot/dts/ti/k3-am6528-iot2050-basic.dts | 5 +++++
arch/arm64/boot/dts/ti/k3-am6548-iot2050-advanced-m2.dts | 5 -----
arch/arm64/boot/dts/ti/k3-am6548-iot2050-advanced-pg2.dts | 7 +------
5 files changed, 12 insertions(+), 17 deletions(-)
@@ -1,6 +1,6 @@
// SPDX-License-Identifier: GPL-2.0
/*
- * Copyright (c) Siemens AG, 2021
+ * Copyright (c) Siemens AG, 2021-2023
*
* Authors:
* Chao Zeng <chao.zeng@siemens.com>
@@ -9,6 +9,11 @@
* Common bits of the IOT2050 Basic and Advanced variants, PG2
*/
+&mcu_r5fss0 {
+ /* lock-step mode not supported on PG2 boards */
+ ti,cluster-mode = <0>;
+};
+
&main_pmx0 {
cp2102n_reset_pin_default: cp2102n-reset-default-pins {
pinctrl-single,pins = <
@@ -54,8 +54,3 @@ &main_uart0 {
pinctrl-names = "default";
pinctrl-0 = <&main_uart0_pins_default>;
};
-
-&mcu_r5fss0 {
- /* lock-step mode not supported on Basic boards */
- ti,cluster-mode = <0>;
-};
@@ -22,3 +22,8 @@ / {
compatible = "siemens,iot2050-basic", "ti,am654";
model = "SIMATIC IOT2050 Basic";
};
+
+&mcu_r5fss0 {
+ /* lock-step mode not supported on this board */
+ ti,cluster-mode = <0>;
+};
@@ -21,11 +21,6 @@ / {
model = "SIMATIC IOT2050 Advanced M2";
};
-&mcu_r5fss0 {
- /* lock-step mode not supported on this board */
- ti,cluster-mode = <0>;
-};
-
&main_pmx0 {
main_bkey_pcie_reset: main-bkey-pcie-reset-default-pins {
pinctrl-single,pins = <
@@ -1,6 +1,6 @@
// SPDX-License-Identifier: GPL-2.0
/*
- * Copyright (c) Siemens AG, 2018-2021
+ * Copyright (c) Siemens AG, 2018-2023
*
* Authors:
* Le Jin <le.jin@siemens.com>
@@ -22,8 +22,3 @@ / {
compatible = "siemens,iot2050-advanced-pg2", "ti,am654";
model = "SIMATIC IOT2050 Advanced PG2";
};
-
-&mcu_r5fss0 {
- /* lock-step mode not supported on this board */
- ti,cluster-mode = <0>;
-};