[v3,04/10] iio: pressure: mprls0025pa fix off-by-one enum
Commit Message
Fix off-by-one error in transfer-function property.
The honeywell,transfer-function property takes values between 1-3 so
make sure the proper enum gets used.
Fixes: <713337d9143ed> ("iio: pressure: Honeywell mprls0025pa pressure sensor")
Co-developed-by: Andreas Klinger <ak@it-klinger.de>
Signed-off-by: Andreas Klinger <ak@it-klinger.de>
Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro>
---
v2 -> v3 no changes
drivers/iio/pressure/mprls0025pa.c | 4 +++-
1 file changed, 3 insertions(+), 1 deletion(-)
--
2.41.0
@@ -323,6 +323,7 @@ static int mpr_probe(struct i2c_client *client)
struct iio_dev *indio_dev;
struct device *dev = &client->dev;
s64 scale, offset;
+ u32 func;
if (!i2c_check_functionality(client->adapter, I2C_FUNC_SMBUS_READ_BYTE))
return dev_err_probe(dev, -EOPNOTSUPP,
@@ -362,10 +363,11 @@ static int mpr_probe(struct i2c_client *client)
return dev_err_probe(dev, ret,
"honeywell,pmax-pascal could not be read\n");
ret = device_property_read_u32(dev,
- "honeywell,transfer-function", &data->function);
+ "honeywell,transfer-function", &func);
if (ret)
return dev_err_probe(dev, ret,
"honeywell,transfer-function could not be read\n");
+ data->function = func - 1;
if (data->function > MPR_FUNCTION_C)
return dev_err_probe(dev, -EINVAL,
"honeywell,transfer-function %d invalid\n",