[v6,1/7] topology: Add a new arch_scale_freq_reference
Commit Message
Create a new method to get a unique and fixed max frequency. Currently
cpuinfo.max_freq or the highest (or last) state of performance domain are
used as the max frequency when computing the frequency for a level of
utilization but:
- cpuinfo_max_freq can change at runtime. boost is one example of
such change.
- cpuinfo.max_freq and last item of the PD can be different leading to
different results between cpufreq and energy model.
We need to save the reference frequency that has been used when computing
the CPUs capacity and use this fixed and coherent value to convert between
frequency and CPU's capacity.
In fact, we already save the frequency that has been used when computing
the capacity of each CPU. We extend the precision to save kHz instead of
MHz currently and we modify the type to be aligned with other variables
used when converting frequency to capacity and the other way.
Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Sudeep Holla <sudeep.holla@arm.com>
---
arch/arm/include/asm/topology.h | 1 +
arch/arm64/include/asm/topology.h | 1 +
arch/riscv/include/asm/topology.h | 1 +
drivers/base/arch_topology.c | 29 ++++++++++++++---------------
include/linux/arch_topology.h | 7 +++++++
include/linux/sched/topology.h | 8 ++++++++
6 files changed, 32 insertions(+), 15 deletions(-)
Comments
Hi Vincent,
I have a small request on this patch, which is useful for [1].
I'll detail what is needed lower in the code.
[1] https://lore.kernel.org/lkml/ZWYDr6JJJzBvsqf0@arm.com/
On Thursday 09 Nov 2023 at 11:14:32 (+0100), Vincent Guittot wrote:
> Create a new method to get a unique and fixed max frequency. Currently
> cpuinfo.max_freq or the highest (or last) state of performance domain are
> used as the max frequency when computing the frequency for a level of
> utilization but:
> - cpuinfo_max_freq can change at runtime. boost is one example of
> such change.
> - cpuinfo.max_freq and last item of the PD can be different leading to
> different results between cpufreq and energy model.
>
> We need to save the reference frequency that has been used when computing
> the CPUs capacity and use this fixed and coherent value to convert between
> frequency and CPU's capacity.
>
> In fact, we already save the frequency that has been used when computing
> the capacity of each CPU. We extend the precision to save kHz instead of
> MHz currently and we modify the type to be aligned with other variables
> used when converting frequency to capacity and the other way.
>
> Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
> Tested-by: Lukasz Luba <lukasz.luba@arm.com>
> Acked-by: Sudeep Holla <sudeep.holla@arm.com>
> ---
> arch/arm/include/asm/topology.h | 1 +
> arch/arm64/include/asm/topology.h | 1 +
> arch/riscv/include/asm/topology.h | 1 +
> drivers/base/arch_topology.c | 29 ++++++++++++++---------------
> include/linux/arch_topology.h | 7 +++++++
> include/linux/sched/topology.h | 8 ++++++++
> 6 files changed, 32 insertions(+), 15 deletions(-)
>
> diff --git a/arch/arm/include/asm/topology.h b/arch/arm/include/asm/topology.h
> index c7d2510e5a78..853c4f81ba4a 100644
> --- a/arch/arm/include/asm/topology.h
> +++ b/arch/arm/include/asm/topology.h
> @@ -13,6 +13,7 @@
> #define arch_set_freq_scale topology_set_freq_scale
> #define arch_scale_freq_capacity topology_get_freq_scale
> #define arch_scale_freq_invariant topology_scale_freq_invariant
> +#define arch_scale_freq_ref topology_get_freq_ref
> #endif
>
> /* Replace task scheduler's default cpu-invariant accounting */
> diff --git a/arch/arm64/include/asm/topology.h b/arch/arm64/include/asm/topology.h
> index 9fab663dd2de..a323b109b9c4 100644
> --- a/arch/arm64/include/asm/topology.h
> +++ b/arch/arm64/include/asm/topology.h
> @@ -23,6 +23,7 @@ void update_freq_counters_refs(void);
> #define arch_set_freq_scale topology_set_freq_scale
> #define arch_scale_freq_capacity topology_get_freq_scale
> #define arch_scale_freq_invariant topology_scale_freq_invariant
> +#define arch_scale_freq_ref topology_get_freq_ref
>
> #ifdef CONFIG_ACPI_CPPC_LIB
> #define arch_init_invariance_cppc topology_init_cpu_capacity_cppc
> diff --git a/arch/riscv/include/asm/topology.h b/arch/riscv/include/asm/topology.h
> index e316ab3b77f3..61183688bdd5 100644
> --- a/arch/riscv/include/asm/topology.h
> +++ b/arch/riscv/include/asm/topology.h
> @@ -9,6 +9,7 @@
> #define arch_set_freq_scale topology_set_freq_scale
> #define arch_scale_freq_capacity topology_get_freq_scale
> #define arch_scale_freq_invariant topology_scale_freq_invariant
> +#define arch_scale_freq_ref topology_get_freq_ref
>
> /* Replace task scheduler's default cpu-invariant accounting */
> #define arch_scale_cpu_capacity topology_get_cpu_scale
> diff --git a/drivers/base/arch_topology.c b/drivers/base/arch_topology.c
> index b741b5ba82bd..e8d1cdf1f761 100644
> --- a/drivers/base/arch_topology.c
> +++ b/drivers/base/arch_topology.c
> @@ -19,6 +19,7 @@
> #include <linux/init.h>
> #include <linux/rcupdate.h>
> #include <linux/sched.h>
> +#include <linux/units.h>
>
> #define CREATE_TRACE_POINTS
> #include <trace/events/thermal_pressure.h>
> @@ -26,7 +27,8 @@
> static DEFINE_PER_CPU(struct scale_freq_data __rcu *, sft_data);
> static struct cpumask scale_freq_counters_mask;
> static bool scale_freq_invariant;
> -static DEFINE_PER_CPU(u32, freq_factor) = 1;
> +DEFINE_PER_CPU(unsigned long, capacity_freq_ref) = 1;
It would be good for this to be initialized to 0 for other users that
might want to detect when capacity_freq_ref was not yet set.
> +EXPORT_PER_CPU_SYMBOL_GPL(capacity_freq_ref);
>
> static bool supports_scale_freq_counters(const struct cpumask *cpus)
> {
> @@ -170,9 +172,9 @@ DEFINE_PER_CPU(unsigned long, thermal_pressure);
> * operating on stale data when hot-plug is used for some CPUs. The
> * @capped_freq reflects the currently allowed max CPUs frequency due to
> * thermal capping. It might be also a boost frequency value, which is bigger
> - * than the internal 'freq_factor' max frequency. In such case the pressure
> - * value should simply be removed, since this is an indication that there is
> - * no thermal throttling. The @capped_freq must be provided in kHz.
> + * than the internal 'capacity_freq_ref' max frequency. In such case the
> + * pressure value should simply be removed, since this is an indication that
> + * there is no thermal throttling. The @capped_freq must be provided in kHz.
> */
> void topology_update_thermal_pressure(const struct cpumask *cpus,
> unsigned long capped_freq)
> @@ -183,10 +185,7 @@ void topology_update_thermal_pressure(const struct cpumask *cpus,
>
> cpu = cpumask_first(cpus);
> max_capacity = arch_scale_cpu_capacity(cpu);
> - max_freq = per_cpu(freq_factor, cpu);
> -
> - /* Convert to MHz scale which is used in 'freq_factor' */
> - capped_freq /= 1000;
> + max_freq = arch_scale_freq_ref(cpu);
>
> /*
> * Handle properly the boost frequencies, which should simply clean
> @@ -279,13 +278,13 @@ void topology_normalize_cpu_scale(void)
>
> capacity_scale = 1;
> for_each_possible_cpu(cpu) {
> - capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
> + capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
The only affected code that I could find is here and below.
The above line would have to change to:
capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu) ?: 1;
> capacity_scale = max(capacity, capacity_scale);
> }
>
> pr_debug("cpu_capacity: capacity_scale=%llu\n", capacity_scale);
> for_each_possible_cpu(cpu) {
> - capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
> + capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
and here:
capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu) ?: 1;
I think it's nicer to start with capacity_freq_ref as 0 and compensate here
for uninitialized capacity_freq_ref.
Let me know if this is alright of if you'd prefer us to make this change
in a separate patch.
Thanks,
Ionela.
> capacity = div64_u64(capacity << SCHED_CAPACITY_SHIFT,
> capacity_scale);
> topology_set_cpu_scale(cpu, capacity);
> @@ -321,15 +320,15 @@ bool __init topology_parse_cpu_capacity(struct device_node *cpu_node, int cpu)
> cpu_node, raw_capacity[cpu]);
>
> /*
> - * Update freq_factor for calculating early boot cpu capacities.
> + * Update capacity_freq_ref for calculating early boot cpu capacities.
> * For non-clk CPU DVFS mechanism, there's no way to get the
> * frequency value now, assuming they are running at the same
> - * frequency (by keeping the initial freq_factor value).
> + * frequency (by keeping the initial capacity_freq_ref value).
> */
> cpu_clk = of_clk_get(cpu_node, 0);
> if (!PTR_ERR_OR_ZERO(cpu_clk)) {
> - per_cpu(freq_factor, cpu) =
> - clk_get_rate(cpu_clk) / 1000;
> + per_cpu(capacity_freq_ref, cpu) =
> + clk_get_rate(cpu_clk) / HZ_PER_KHZ;
> clk_put(cpu_clk);
> }
> } else {
> @@ -411,7 +410,7 @@ init_cpu_capacity_callback(struct notifier_block *nb,
> cpumask_andnot(cpus_to_visit, cpus_to_visit, policy->related_cpus);
>
> for_each_cpu(cpu, policy->related_cpus)
> - per_cpu(freq_factor, cpu) = policy->cpuinfo.max_freq / 1000;
> + per_cpu(capacity_freq_ref, cpu) = policy->cpuinfo.max_freq;
>
> if (cpumask_empty(cpus_to_visit)) {
> topology_normalize_cpu_scale();
> diff --git a/include/linux/arch_topology.h b/include/linux/arch_topology.h
> index a07b510e7dc5..32c24ff4f2a8 100644
> --- a/include/linux/arch_topology.h
> +++ b/include/linux/arch_topology.h
> @@ -27,6 +27,13 @@ static inline unsigned long topology_get_cpu_scale(int cpu)
>
> void topology_set_cpu_scale(unsigned int cpu, unsigned long capacity);
>
> +DECLARE_PER_CPU(unsigned long, capacity_freq_ref);
> +
> +static inline unsigned long topology_get_freq_ref(int cpu)
> +{
> + return per_cpu(capacity_freq_ref, cpu);
> +}
> +
> DECLARE_PER_CPU(unsigned long, arch_freq_scale);
>
> static inline unsigned long topology_get_freq_scale(int cpu)
> diff --git a/include/linux/sched/topology.h b/include/linux/sched/topology.h
> index de545ba85218..a6e04b4a21d7 100644
> --- a/include/linux/sched/topology.h
> +++ b/include/linux/sched/topology.h
> @@ -279,6 +279,14 @@ void arch_update_thermal_pressure(const struct cpumask *cpus,
> { }
> #endif
>
> +#ifndef arch_scale_freq_ref
> +static __always_inline
> +unsigned int arch_scale_freq_ref(int cpu)
> +{
> + return 0;
> +}
> +#endif
> +
> static inline int task_node(const struct task_struct *p)
> {
> return cpu_to_node(task_cpu(p));
> --
> 2.34.1
>
On Tuesday 28 Nov 2023 at 15:52:52 (+0000), Ionela Voinescu wrote:
> Hi Vincent,
>
> I have a small request on this patch, which is useful for [1].
> I'll detail what is needed lower in the code.
>
> [1] https://lore.kernel.org/lkml/ZWYDr6JJJzBvsqf0@arm.com/
>
> On Thursday 09 Nov 2023 at 11:14:32 (+0100), Vincent Guittot wrote:
> > @@ -279,13 +278,13 @@ void topology_normalize_cpu_scale(void)
> >
> > capacity_scale = 1;
> > for_each_possible_cpu(cpu) {
> > - capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
> > + capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
>
> The only affected code that I could find is here and below.
>
> The above line would have to change to:
> capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu) ?: 1;
>
> > capacity_scale = max(capacity, capacity_scale);
> > }
> >
> > pr_debug("cpu_capacity: capacity_scale=%llu\n", capacity_scale);
> > for_each_possible_cpu(cpu) {
> > - capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
> > + capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
>
> and here:
> capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu) ?: 1;
>
> I think it's nicer to start with capacity_freq_ref as 0 and compensate here
> for uninitialized capacity_freq_ref.
>
> Let me know if this is alright of if you'd prefer us to make this change
> in a separate patch.
>
> Thanks,
> Ionela.
>
Correction - both will need to be:
capacity = raw_capacity[cpu] * (per_cpu(capacity_freq_ref, cpu) ?: 1);
Thanks,
Ionela.
Hi Ionela,
On Tue, 28 Nov 2023 at 17:00, Ionela Voinescu <ionela.voinescu@arm.com> wrote:
>
> On Tuesday 28 Nov 2023 at 15:52:52 (+0000), Ionela Voinescu wrote:
> > Hi Vincent,
> >
> > I have a small request on this patch, which is useful for [1].
> > I'll detail what is needed lower in the code.
> >
> > [1] https://lore.kernel.org/lkml/ZWYDr6JJJzBvsqf0@arm.com/
> >
> > On Thursday 09 Nov 2023 at 11:14:32 (+0100), Vincent Guittot wrote:
> > > @@ -279,13 +278,13 @@ void topology_normalize_cpu_scale(void)
> > >
> > > capacity_scale = 1;
> > > for_each_possible_cpu(cpu) {
> > > - capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
> > > + capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
> >
> > The only affected code that I could find is here and below.
> >
> > The above line would have to change to:
> > capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu) ?: 1;
> >
> > > capacity_scale = max(capacity, capacity_scale);
> > > }
> > >
> > > pr_debug("cpu_capacity: capacity_scale=%llu\n", capacity_scale);
> > > for_each_possible_cpu(cpu) {
> > > - capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
> > > + capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
> >
> > and here:
> > capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu) ?: 1;
> >
> > I think it's nicer to start with capacity_freq_ref as 0 and compensate here
> > for uninitialized capacity_freq_ref.
> >
> > Let me know if this is alright of if you'd prefer us to make this change
> > in a separate patch.
> >
> > Thanks,
> > Ionela.
> >
>
> Correction - both will need to be:
> capacity = raw_capacity[cpu] * (per_cpu(capacity_freq_ref, cpu) ?: 1);
Yes, this one is better to keep the same behavior when cpufreq driver
is never loaded
I think this change should come as an additional patch either on top
of this series or directly as part of [1] which is the main user of
the change. I assume that's because you want arch_freq_get_on_cpu()
returns 0 until everything has been initialized
Vincent
>
> Thanks,
> Ionela.
@@ -13,6 +13,7 @@
#define arch_set_freq_scale topology_set_freq_scale
#define arch_scale_freq_capacity topology_get_freq_scale
#define arch_scale_freq_invariant topology_scale_freq_invariant
+#define arch_scale_freq_ref topology_get_freq_ref
#endif
/* Replace task scheduler's default cpu-invariant accounting */
@@ -23,6 +23,7 @@ void update_freq_counters_refs(void);
#define arch_set_freq_scale topology_set_freq_scale
#define arch_scale_freq_capacity topology_get_freq_scale
#define arch_scale_freq_invariant topology_scale_freq_invariant
+#define arch_scale_freq_ref topology_get_freq_ref
#ifdef CONFIG_ACPI_CPPC_LIB
#define arch_init_invariance_cppc topology_init_cpu_capacity_cppc
@@ -9,6 +9,7 @@
#define arch_set_freq_scale topology_set_freq_scale
#define arch_scale_freq_capacity topology_get_freq_scale
#define arch_scale_freq_invariant topology_scale_freq_invariant
+#define arch_scale_freq_ref topology_get_freq_ref
/* Replace task scheduler's default cpu-invariant accounting */
#define arch_scale_cpu_capacity topology_get_cpu_scale
@@ -19,6 +19,7 @@
#include <linux/init.h>
#include <linux/rcupdate.h>
#include <linux/sched.h>
+#include <linux/units.h>
#define CREATE_TRACE_POINTS
#include <trace/events/thermal_pressure.h>
@@ -26,7 +27,8 @@
static DEFINE_PER_CPU(struct scale_freq_data __rcu *, sft_data);
static struct cpumask scale_freq_counters_mask;
static bool scale_freq_invariant;
-static DEFINE_PER_CPU(u32, freq_factor) = 1;
+DEFINE_PER_CPU(unsigned long, capacity_freq_ref) = 1;
+EXPORT_PER_CPU_SYMBOL_GPL(capacity_freq_ref);
static bool supports_scale_freq_counters(const struct cpumask *cpus)
{
@@ -170,9 +172,9 @@ DEFINE_PER_CPU(unsigned long, thermal_pressure);
* operating on stale data when hot-plug is used for some CPUs. The
* @capped_freq reflects the currently allowed max CPUs frequency due to
* thermal capping. It might be also a boost frequency value, which is bigger
- * than the internal 'freq_factor' max frequency. In such case the pressure
- * value should simply be removed, since this is an indication that there is
- * no thermal throttling. The @capped_freq must be provided in kHz.
+ * than the internal 'capacity_freq_ref' max frequency. In such case the
+ * pressure value should simply be removed, since this is an indication that
+ * there is no thermal throttling. The @capped_freq must be provided in kHz.
*/
void topology_update_thermal_pressure(const struct cpumask *cpus,
unsigned long capped_freq)
@@ -183,10 +185,7 @@ void topology_update_thermal_pressure(const struct cpumask *cpus,
cpu = cpumask_first(cpus);
max_capacity = arch_scale_cpu_capacity(cpu);
- max_freq = per_cpu(freq_factor, cpu);
-
- /* Convert to MHz scale which is used in 'freq_factor' */
- capped_freq /= 1000;
+ max_freq = arch_scale_freq_ref(cpu);
/*
* Handle properly the boost frequencies, which should simply clean
@@ -279,13 +278,13 @@ void topology_normalize_cpu_scale(void)
capacity_scale = 1;
for_each_possible_cpu(cpu) {
- capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
+ capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
capacity_scale = max(capacity, capacity_scale);
}
pr_debug("cpu_capacity: capacity_scale=%llu\n", capacity_scale);
for_each_possible_cpu(cpu) {
- capacity = raw_capacity[cpu] * per_cpu(freq_factor, cpu);
+ capacity = raw_capacity[cpu] * per_cpu(capacity_freq_ref, cpu);
capacity = div64_u64(capacity << SCHED_CAPACITY_SHIFT,
capacity_scale);
topology_set_cpu_scale(cpu, capacity);
@@ -321,15 +320,15 @@ bool __init topology_parse_cpu_capacity(struct device_node *cpu_node, int cpu)
cpu_node, raw_capacity[cpu]);
/*
- * Update freq_factor for calculating early boot cpu capacities.
+ * Update capacity_freq_ref for calculating early boot cpu capacities.
* For non-clk CPU DVFS mechanism, there's no way to get the
* frequency value now, assuming they are running at the same
- * frequency (by keeping the initial freq_factor value).
+ * frequency (by keeping the initial capacity_freq_ref value).
*/
cpu_clk = of_clk_get(cpu_node, 0);
if (!PTR_ERR_OR_ZERO(cpu_clk)) {
- per_cpu(freq_factor, cpu) =
- clk_get_rate(cpu_clk) / 1000;
+ per_cpu(capacity_freq_ref, cpu) =
+ clk_get_rate(cpu_clk) / HZ_PER_KHZ;
clk_put(cpu_clk);
}
} else {
@@ -411,7 +410,7 @@ init_cpu_capacity_callback(struct notifier_block *nb,
cpumask_andnot(cpus_to_visit, cpus_to_visit, policy->related_cpus);
for_each_cpu(cpu, policy->related_cpus)
- per_cpu(freq_factor, cpu) = policy->cpuinfo.max_freq / 1000;
+ per_cpu(capacity_freq_ref, cpu) = policy->cpuinfo.max_freq;
if (cpumask_empty(cpus_to_visit)) {
topology_normalize_cpu_scale();
@@ -27,6 +27,13 @@ static inline unsigned long topology_get_cpu_scale(int cpu)
void topology_set_cpu_scale(unsigned int cpu, unsigned long capacity);
+DECLARE_PER_CPU(unsigned long, capacity_freq_ref);
+
+static inline unsigned long topology_get_freq_ref(int cpu)
+{
+ return per_cpu(capacity_freq_ref, cpu);
+}
+
DECLARE_PER_CPU(unsigned long, arch_freq_scale);
static inline unsigned long topology_get_freq_scale(int cpu)
@@ -279,6 +279,14 @@ void arch_update_thermal_pressure(const struct cpumask *cpus,
{ }
#endif
+#ifndef arch_scale_freq_ref
+static __always_inline
+unsigned int arch_scale_freq_ref(int cpu)
+{
+ return 0;
+}
+#endif
+
static inline int task_node(const struct task_struct *p)
{
return cpu_to_node(task_cpu(p));