[v2,04/16] dt-bindings: watchdog: Fix node descriptions in uniphier-wdt example

Message ID 20221207055405.30940-5-hayashi.kunihiko@socionext.com
State New
Headers
Series dt-bindings: soc: Introduce UniPhier miscellaneous register blocks and fix examples |

Commit Message

Kunihiko Hayashi Dec. 7, 2022, 5:53 a.m. UTC
  Rename the parent node to the generic node name "syscon".

Signed-off-by: Kunihiko Hayashi <hayashi.kunihiko@socionext.com>
---
 .../devicetree/bindings/watchdog/socionext,uniphier-wdt.yaml    | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
  

Patch

diff --git a/Documentation/devicetree/bindings/watchdog/socionext,uniphier-wdt.yaml b/Documentation/devicetree/bindings/watchdog/socionext,uniphier-wdt.yaml
index 90698cfa8f94..33fb94f9c730 100644
--- a/Documentation/devicetree/bindings/watchdog/socionext,uniphier-wdt.yaml
+++ b/Documentation/devicetree/bindings/watchdog/socionext,uniphier-wdt.yaml
@@ -25,7 +25,7 @@  examples:
   - |
     // The UniPhier watchdog should be a subnode of a "syscon" compatible node.
 
-    sysctrl@61840000 {
+    syscon@61840000 {
         compatible = "socionext,uniphier-ld11-sysctrl",
                      "simple-mfd", "syscon";
         reg = <0x61840000 0x10000>;