thermal: Use of_property_present() for testing DT property presence

Message ID 20230310144726.1545543-1-robh@kernel.org
State New
Headers
Series thermal: Use of_property_present() for testing DT property presence |

Commit Message

Rob Herring March 10, 2023, 2:47 p.m. UTC
  It is preferred to use typed property access functions (i.e.
of_property_read_<type> functions) rather than low-level
of_get_property/of_find_property functions for reading properties. As
part of this, convert of_get_property/of_find_property calls to the
recently added of_property_present() helper when we just want to test
for presence of a property and nothing more.

Signed-off-by: Rob Herring <robh@kernel.org>
---
 drivers/thermal/cpufreq_cooling.c                  | 2 +-
 drivers/thermal/imx8mm_thermal.c                   | 2 +-
 drivers/thermal/imx_thermal.c                      | 4 ++--
 drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 2 +-
 4 files changed, 5 insertions(+), 5 deletions(-)
  

Comments

Viresh Kumar March 13, 2023, 4:29 a.m. UTC | #1
On 10-03-23, 08:47, Rob Herring wrote:
> It is preferred to use typed property access functions (i.e.
> of_property_read_<type> functions) rather than low-level
> of_get_property/of_find_property functions for reading properties. As
> part of this, convert of_get_property/of_find_property calls to the
> recently added of_property_present() helper when we just want to test
> for presence of a property and nothing more.
> 
> Signed-off-by: Rob Herring <robh@kernel.org>
> ---
>  drivers/thermal/cpufreq_cooling.c                  | 2 +-
>  drivers/thermal/imx8mm_thermal.c                   | 2 +-
>  drivers/thermal/imx_thermal.c                      | 4 ++--
>  drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 2 +-
>  4 files changed, 5 insertions(+), 5 deletions(-)

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
  
Rafael J. Wysocki March 27, 2023, 5:13 p.m. UTC | #2
On Fri, Mar 10, 2023 at 3:48 PM Rob Herring <robh@kernel.org> wrote:
>
> It is preferred to use typed property access functions (i.e.
> of_property_read_<type> functions) rather than low-level
> of_get_property/of_find_property functions for reading properties. As
> part of this, convert of_get_property/of_find_property calls to the
> recently added of_property_present() helper when we just want to test
> for presence of a property and nothing more.
>
> Signed-off-by: Rob Herring <robh@kernel.org>

Daniel, are you going to apply this, or should I take it directly?

> ---
>  drivers/thermal/cpufreq_cooling.c                  | 2 +-
>  drivers/thermal/imx8mm_thermal.c                   | 2 +-
>  drivers/thermal/imx_thermal.c                      | 4 ++--
>  drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 2 +-
>  4 files changed, 5 insertions(+), 5 deletions(-)
>
> diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
> index 9f8b438fcf8f..4608555b7ec3 100644
> --- a/drivers/thermal/cpufreq_cooling.c
> +++ b/drivers/thermal/cpufreq_cooling.c
> @@ -633,7 +633,7 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy)
>                 return NULL;
>         }
>
> -       if (of_find_property(np, "#cooling-cells", NULL)) {
> +       if (of_property_present(np, "#cooling-cells")) {
>                 struct em_perf_domain *em = em_cpu_get(policy->cpu);
>
>                 cdev = __cpufreq_cooling_register(np, policy, em);
> diff --git a/drivers/thermal/imx8mm_thermal.c b/drivers/thermal/imx8mm_thermal.c
> index 72b5d6f319c1..334ce8e9830b 100644
> --- a/drivers/thermal/imx8mm_thermal.c
> +++ b/drivers/thermal/imx8mm_thermal.c
> @@ -282,7 +282,7 @@ static int imx8mm_tmu_probe_set_calib(struct platform_device *pdev,
>          * strongly recommended to update such old DTs to get correct
>          * temperature compensation values for each SoC.
>          */
> -       if (!of_find_property(pdev->dev.of_node, "nvmem-cells", NULL)) {
> +       if (!of_property_present(pdev->dev.of_node, "nvmem-cells")) {
>                 dev_warn(dev,
>                          "No OCOTP nvmem reference found, SoC-specific calibration not loaded. Please update your DT.\n");
>                 return 0;
> diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
> index fb0d5cab70af..77d6567a3f47 100644
> --- a/drivers/thermal/imx_thermal.c
> +++ b/drivers/thermal/imx_thermal.c
> @@ -594,7 +594,7 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
>
>         np = of_get_cpu_node(data->policy->cpu, NULL);
>
> -       if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
> +       if (!np || !of_property_present(np, "#cooling-cells")) {
>                 data->cdev = cpufreq_cooling_register(data->policy);
>                 if (IS_ERR(data->cdev)) {
>                         ret = PTR_ERR(data->cdev);
> @@ -671,7 +671,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
>
>         platform_set_drvdata(pdev, data);
>
> -       if (of_find_property(pdev->dev.of_node, "nvmem-cells", NULL)) {
> +       if (of_property_present(pdev->dev.of_node, "nvmem-cells")) {
>                 ret = imx_init_from_nvmem_cells(pdev);
>                 if (ret)
>                         return dev_err_probe(&pdev->dev, ret,
> diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
> index 8a9055bd376e..dace6591220e 100644
> --- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
> +++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
> @@ -223,7 +223,7 @@ int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
>          * using DT, then it must be aware that the cooling device
>          * loading has to happen via cpufreq driver.
>          */
> -       if (of_find_property(np, "#thermal-sensor-cells", NULL))
> +       if (of_property_present(np, "#thermal-sensor-cells"))
>                 return 0;
>
>         data = ti_bandgap_get_sensor_data(bgp, id);
> --
> 2.39.2
>
  
Rafael J. Wysocki March 30, 2023, 5:28 p.m. UTC | #3
On Mon, Mar 27, 2023 at 7:13 PM Rafael J. Wysocki <rafael@kernel.org> wrote:
>
> On Fri, Mar 10, 2023 at 3:48 PM Rob Herring <robh@kernel.org> wrote:
> >
> > It is preferred to use typed property access functions (i.e.
> > of_property_read_<type> functions) rather than low-level
> > of_get_property/of_find_property functions for reading properties. As
> > part of this, convert of_get_property/of_find_property calls to the
> > recently added of_property_present() helper when we just want to test
> > for presence of a property and nothing more.
> >
> > Signed-off-by: Rob Herring <robh@kernel.org>
>
> Daniel, are you going to apply this, or should I take it directly?

Applied as 6.4 material, thanks!

> > ---
> >  drivers/thermal/cpufreq_cooling.c                  | 2 +-
> >  drivers/thermal/imx8mm_thermal.c                   | 2 +-
> >  drivers/thermal/imx_thermal.c                      | 4 ++--
> >  drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 2 +-
> >  4 files changed, 5 insertions(+), 5 deletions(-)
> >
> > diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
> > index 9f8b438fcf8f..4608555b7ec3 100644
> > --- a/drivers/thermal/cpufreq_cooling.c
> > +++ b/drivers/thermal/cpufreq_cooling.c
> > @@ -633,7 +633,7 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy)
> >                 return NULL;
> >         }
> >
> > -       if (of_find_property(np, "#cooling-cells", NULL)) {
> > +       if (of_property_present(np, "#cooling-cells")) {
> >                 struct em_perf_domain *em = em_cpu_get(policy->cpu);
> >
> >                 cdev = __cpufreq_cooling_register(np, policy, em);
> > diff --git a/drivers/thermal/imx8mm_thermal.c b/drivers/thermal/imx8mm_thermal.c
> > index 72b5d6f319c1..334ce8e9830b 100644
> > --- a/drivers/thermal/imx8mm_thermal.c
> > +++ b/drivers/thermal/imx8mm_thermal.c
> > @@ -282,7 +282,7 @@ static int imx8mm_tmu_probe_set_calib(struct platform_device *pdev,
> >          * strongly recommended to update such old DTs to get correct
> >          * temperature compensation values for each SoC.
> >          */
> > -       if (!of_find_property(pdev->dev.of_node, "nvmem-cells", NULL)) {
> > +       if (!of_property_present(pdev->dev.of_node, "nvmem-cells")) {
> >                 dev_warn(dev,
> >                          "No OCOTP nvmem reference found, SoC-specific calibration not loaded. Please update your DT.\n");
> >                 return 0;
> > diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
> > index fb0d5cab70af..77d6567a3f47 100644
> > --- a/drivers/thermal/imx_thermal.c
> > +++ b/drivers/thermal/imx_thermal.c
> > @@ -594,7 +594,7 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
> >
> >         np = of_get_cpu_node(data->policy->cpu, NULL);
> >
> > -       if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
> > +       if (!np || !of_property_present(np, "#cooling-cells")) {
> >                 data->cdev = cpufreq_cooling_register(data->policy);
> >                 if (IS_ERR(data->cdev)) {
> >                         ret = PTR_ERR(data->cdev);
> > @@ -671,7 +671,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
> >
> >         platform_set_drvdata(pdev, data);
> >
> > -       if (of_find_property(pdev->dev.of_node, "nvmem-cells", NULL)) {
> > +       if (of_property_present(pdev->dev.of_node, "nvmem-cells")) {
> >                 ret = imx_init_from_nvmem_cells(pdev);
> >                 if (ret)
> >                         return dev_err_probe(&pdev->dev, ret,
> > diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
> > index 8a9055bd376e..dace6591220e 100644
> > --- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
> > +++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
> > @@ -223,7 +223,7 @@ int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
> >          * using DT, then it must be aware that the cooling device
> >          * loading has to happen via cpufreq driver.
> >          */
> > -       if (of_find_property(np, "#thermal-sensor-cells", NULL))
> > +       if (of_property_present(np, "#thermal-sensor-cells"))
> >                 return 0;
> >
> >         data = ti_bandgap_get_sensor_data(bgp, id);
> > --
> > 2.39.2
> >
  
Daniel Lezcano March 31, 2023, 8:44 a.m. UTC | #4
On 30/03/2023 19:28, Rafael J. Wysocki wrote:
> On Mon, Mar 27, 2023 at 7:13 PM Rafael J. Wysocki <rafael@kernel.org> wrote:
>>
>> On Fri, Mar 10, 2023 at 3:48 PM Rob Herring <robh@kernel.org> wrote:
>>>
>>> It is preferred to use typed property access functions (i.e.
>>> of_property_read_<type> functions) rather than low-level
>>> of_get_property/of_find_property functions for reading properties. As
>>> part of this, convert of_get_property/of_find_property calls to the
>>> recently added of_property_present() helper when we just want to test
>>> for presence of a property and nothing more.
>>>
>>> Signed-off-by: Rob Herring <robh@kernel.org>
>>
>> Daniel, are you going to apply this, or should I take it directly?
> 
> Applied as 6.4 material, thanks

Sorry, I forgot to answer. I already applied it.

Shall I drop it from my branch ?
  
Rafael J. Wysocki March 31, 2023, 9:04 a.m. UTC | #5
On Fri, Mar 31, 2023 at 10:44 AM Daniel Lezcano
<daniel.lezcano@linaro.org> wrote:
>
> On 30/03/2023 19:28, Rafael J. Wysocki wrote:
> > On Mon, Mar 27, 2023 at 7:13 PM Rafael J. Wysocki <rafael@kernel.org> wrote:
> >>
> >> On Fri, Mar 10, 2023 at 3:48 PM Rob Herring <robh@kernel.org> wrote:
> >>>
> >>> It is preferred to use typed property access functions (i.e.
> >>> of_property_read_<type> functions) rather than low-level
> >>> of_get_property/of_find_property functions for reading properties. As
> >>> part of this, convert of_get_property/of_find_property calls to the
> >>> recently added of_property_present() helper when we just want to test
> >>> for presence of a property and nothing more.
> >>>
> >>> Signed-off-by: Rob Herring <robh@kernel.org>
> >>
> >> Daniel, are you going to apply this, or should I take it directly?
> >
> > Applied as 6.4 material, thanks
>
> Sorry, I forgot to answer. I already applied it.
>
> Shall I drop it from my branch ?

If you can do that, then yes, please.
  

Patch

diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
index 9f8b438fcf8f..4608555b7ec3 100644
--- a/drivers/thermal/cpufreq_cooling.c
+++ b/drivers/thermal/cpufreq_cooling.c
@@ -633,7 +633,7 @@  of_cpufreq_cooling_register(struct cpufreq_policy *policy)
 		return NULL;
 	}
 
-	if (of_find_property(np, "#cooling-cells", NULL)) {
+	if (of_property_present(np, "#cooling-cells")) {
 		struct em_perf_domain *em = em_cpu_get(policy->cpu);
 
 		cdev = __cpufreq_cooling_register(np, policy, em);
diff --git a/drivers/thermal/imx8mm_thermal.c b/drivers/thermal/imx8mm_thermal.c
index 72b5d6f319c1..334ce8e9830b 100644
--- a/drivers/thermal/imx8mm_thermal.c
+++ b/drivers/thermal/imx8mm_thermal.c
@@ -282,7 +282,7 @@  static int imx8mm_tmu_probe_set_calib(struct platform_device *pdev,
 	 * strongly recommended to update such old DTs to get correct
 	 * temperature compensation values for each SoC.
 	 */
-	if (!of_find_property(pdev->dev.of_node, "nvmem-cells", NULL)) {
+	if (!of_property_present(pdev->dev.of_node, "nvmem-cells")) {
 		dev_warn(dev,
 			 "No OCOTP nvmem reference found, SoC-specific calibration not loaded. Please update your DT.\n");
 		return 0;
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index fb0d5cab70af..77d6567a3f47 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -594,7 +594,7 @@  static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 
 	np = of_get_cpu_node(data->policy->cpu, NULL);
 
-	if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
+	if (!np || !of_property_present(np, "#cooling-cells")) {
 		data->cdev = cpufreq_cooling_register(data->policy);
 		if (IS_ERR(data->cdev)) {
 			ret = PTR_ERR(data->cdev);
@@ -671,7 +671,7 @@  static int imx_thermal_probe(struct platform_device *pdev)
 
 	platform_set_drvdata(pdev, data);
 
-	if (of_find_property(pdev->dev.of_node, "nvmem-cells", NULL)) {
+	if (of_property_present(pdev->dev.of_node, "nvmem-cells")) {
 		ret = imx_init_from_nvmem_cells(pdev);
 		if (ret)
 			return dev_err_probe(&pdev->dev, ret,
diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
index 8a9055bd376e..dace6591220e 100644
--- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
+++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
@@ -223,7 +223,7 @@  int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
 	 * using DT, then it must be aware that the cooling device
 	 * loading has to happen via cpufreq driver.
 	 */
-	if (of_find_property(np, "#thermal-sensor-cells", NULL))
+	if (of_property_present(np, "#thermal-sensor-cells"))
 		return 0;
 
 	data = ti_bandgap_get_sensor_data(bgp, id);